ER05

FAILURE TO RELEASE PRESSURE

CAUSE SOLUTION VIDEO
TUTORIAL
1 CHAMBER FILTER CLEAN THE FILTER
2 N.O. VALVE CHECK, CLEAN OR REPLACE THE N.O. VALVE
3 CABLE N.O. VALVE CHECK THE CONNECTION NO NEED
4 MAIN BOARD SIGNAL FOR N.O. VALVE CHECK THE SIGNAL OR REPLACE THE MAIN BOARD
5 3 WAY VALVE CHECK, CLEAN OR REPLACE THE 3 WAY VALVE